After long-term operation of the gear oil pump, the internal parts will cause internal leakage, which is generally leaked between the gear end face and the thrust plate. As the internal wear gap increases, the self-priming ability of the gear pump will be worse and the pressure will be higher. The lower the flow, the smaller the gear pump flow. The internal leakage of the gear oil pump causes the pressure and flow to become smaller. The leakage area between the floating bushing and the gear end face is large, causing the main part of the internal leakage. This part of the leakage accounted for about 50% to 70% of the total internal leakage. The gear oil pump with worn inner leakage has a lower volumetric efficiency, and the output power of the oil pump is much lower than the input power. All of its losses are converted into heat, which can cause the gear pump to overheat. If the joint plane is pressed, the floating sleeve will wear due to a small amount of movement during operation, and as a result, the pressure flow will decrease, and such a floating sleeve must be replaced or repaired.

1. The four bearing sleeves in the gear oil pump are floatingly installed in the pump body, and the end face interval is automatically adjusted according to the working pressure. Therefore, the pressure of the pump is stable, the output flow pulsation is small, and the volumetric efficiency is high.

2. The gear oil pump is mainly composed of gears, shafts, pump bodies, pump covers, bearing sleeves, shaft end seals and other components. The gears and shafts are subjected to strict heat treatment, have high hardness and wear resistance, and are installed in the bushing together with the shaft. All moving parts in the pump are lubricated with the medium they transport.

3. Regularly check the gear pump gear and thrust plate wear.

4. In particular, when conveying media with poor lubricity, please specify when ordering. In order to use the special wear-resistant material for the medium flow parts that the gear oil pump is exposed to during the production process.

Περιέγερση ΗΠΑ

Συγγραφέας:

Mr. Bruce Tang

ΗΛΕΚΤΡΟΝΙΚΗ ΔΙΕΥΘΥΝΣΗ:

bruce.tang@macxipump.com

Phone/WhatsApp:

+8613773149257

δημοφιλή Προϊόντα
Μπορεί επίσης να σας αρέσει
Σχετικές κατηγορίες

ΗΛΕΚΤΡΟΝΙΚΗ ΔΙΕΥΘΥΝΣΗ σε αυτόν τον προμηθευτή

Θέμα:
ΗΛΕΚΤΡΟΝΙΚΗ ΔΙΕΥΘΥΝΣΗ:
μήνυμα:

Το μήνυμά σας MSS

Περιέγερση ΗΠΑ

Συγγραφέας:

Mr. Bruce Tang

ΗΛΕΚΤΡΟΝΙΚΗ ΔΙΕΥΘΥΝΣΗ:

bruce.tang@macxipump.com

Phone/WhatsApp:

+8613773149257

δημοφιλή Προϊόντα

Σπίτι

Product

Whatsapp

Σχετικά με εμάς

Έρευνα

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Αποστολή